10
Technical data and dimension drawings
Port overview
Manual – DHE/DHF/DHR21B (standard) and DHE/DHF/DHR41B (advanced)
80
Stand-alone device
Electrical supply
X26: V = DC24V (–15% / +20%), DGND must be grounded (PELV)
Power consumption P
max
= 8.5W, I
max
= 600mA
X31: Supply the digital inputs and outputs separately with DC24V.
INFORMATION
The CAN 1 system bus is connected in parallel to X33 and X26.
The RS485 interface COM1 is connected in parallel to X34 and X24.
For further technical data, refer to chapter "Technical data of the DH.21B/41B
option card"(→276).
10.6 Port overview
10.6.1 PROFINET
Port TCP/
UDP
Function Authorization
Ethertype 8892hex Process data exchange Controlling connection
Dynamic
port defini-
tion via End
Point Map-
per
UDP PROFINET DCE/RPC Reading and writing on all indexed parameters
23 TCP Telnet Reading OEM diagnostic data
80 TCP http The Java application uses SMLP via Port 300,
reading and writing IP parameters,
reading and writing indexed parameters
161 UDP SNMP Reading on MIBs
300 TCP SMLP (MOVILINK
®
on Ethernet) Reading and writing of all parameters
300 UDP Address Editor Reading and writing the IP parameters
10.6.2 EtherNet/IP™, Modbus/TCP
Port TCP/
UDP
Function Authorization
Ethertype 80E1hex ODVA ring redundancy protocol DLR Reading and writing the ring redundancy para-
meter
23 TCP Telnet Reading OEM diagnostic data
80 TCP http The Java application uses SMLP via Port 300,
reading and writing IP parameters,
reading and writing indexed parameters
300 TCP SMLP (MOVILINK
®
on Ethernet) Reading and writing of all parameters
300 UDP Address Editor Reading and writing the IP parameters
22900055/EN – 08/2016