Operating Instructions FLOWSIC100
Gas Velocity Monitor
Assembly and Installation
88012513/03-2008 © SICK MAIHAK GmbH · Germany · All rights reserved 63
3.2 Assembly
All of the assembly and installation work has to be carried out by the customer. This in-
cludes:
Installing the flanges with pipe or glands for high-pressure versions
Mounting the evaluation unit
Mounting the optional purge-air unit
Installing weatherproof covers
DANGER
Warning
When carrying out assembly and installation work, observe the relevant safety regula-
tions and the safety information in Chapter 1!
Assembly and installation work on potentially dangerous installations (hot or corrosive
gases, high internal duct pressure) must only be carried out when the plant is shut down!
Suitable measures must be taken to protect against local or installation-specific
hazards!
3.2.1 Installing the Flanges with Pipe
3.2.1.1 Duct/pipe diameter > 0.5 m
Activities
Measure out the mounting locations in such a way that the planned installation angle is
reached (if mounting two flanges with pipe, observe the diameter) and mark the moun-
ting location.
Remove the insulation (if present).
Cut out suitable oval openings (apertures) in the duct wall; with brick and concrete ducts,
drill suitably sized holes (see Appendix for templates).
ATTENTION
Important
Make sure that parts do not fall into the duct!
Insert the flange with pipe in the aperture as shown in Fig. 3.8,
observe the minimum draw-in length Le (>20 mm or as shown in Fig. 3.7 and table),
roughly align it and tack it into position with a few spot welds,
–with brick and concrete ducts, tack it to a holding plate (see Fig. 3.9)
Fig. 3.8: Installation options for the flanges with pipe
A
A
A
Duct / pipe wall
Insulation (remove around flange area)
Note:
For the installation of
sender / receiver units
FLSE100-PR and PRAC,
the flange with pipe must
be inserted into the duct
with the longest possible
draw in length Le.