The application-specific P
lausibility testSAPP-FB function block checks whether the posi‐
tion data from the sensor is plausible.
The process control uses test signals to check whether the standstill and direction condi‐
tions read (from the SSI position data) are plausible.
In addition, the sensors generate their own standstill signal, which they transmit to the
Flexi Soft safety controller via the digital outputs (sensor ID signal). These standstill signals
are also used for the plausibility check.
Table 47: Function of the inputs
Input name Function
Test signal 1 KF100.1 test signal 1 from the process control
Test signal 2 KF100.2 test signal 2 from the process control
Sensor2 test active Sensor2_test active jum
p address from Plausibility test SAPP-FB
Sensor ID Standstill Status Standstill from SensorID jum
p address from Sensor ID SAPP-FB
Sensor 1 Direction Status Sensor 1 direction information from the MOC1 logic
Sensor 2 Direction Status Sensor 2 direction information from the MOC1 logic
Sensor 1 Standstill Status Sensor 1 standstill information from the MOC1 logic
Sensor 2 Standstill Status Sensor 2 standstill information from the MOC1 logic
Table 48: Function of the output
Output name Function
Plausibility test error Result of the plausibility check
7.5.4.2 Sensor2 test SAPP-FB function block
The application-specific S
ensor2 test SAPP-FB function block detects systematic faults
that occur on both sensors at the same time. In the case of this kind of fault, the posi‐
tion data can freeze the two sensors and output a static position. This would be inter‐
preted as a standstill.
Test procedure:
After a relatively long inactive phase, Flexi Soft sends a query signal to sensor 2 as a
test. The sensor then performs an internal test. Flexi Soft can use the data read at the
SSI interface to check that the test has been performed successfully and that the test
results coincide with the expectations.
Figure 31: Function block view - Sensor2 test SAPP-FB
Table 49: Function of the inputs
Input name Function
Standstill Sensor 2 Sensor 2 standstill information from the MOC1 logic
SS1 request LowActive SS1 request LowActive jum
p address from Sensor2 test SAPP-FB
SS2 request LowActive SS2 request LowActive jum
p address from Sensor2 test SAPP-FB
Sensor2 _test_active Sensor2_test_active jump address from Sensor2 test SAPP-FB output
7 CONFIGURATION
58
O P E R A T I N G I N S T R U C T I O N S | Safe Linear Positioning 8020941/12O9/2019-08-05 | SICK
Subject to change without notice