6 COMMISSIONING
8017768/12AX/2019-05-31|SICK
OPERATING INSTRUCTIONS | TIC
Subject to change without notice
6.6.2.3 Assigning devices to vehicle detection components
Manual assignment of the 2D LiDAR sensors to the components of a system function is
required if the measurement site contains more than one TIC102 Slave or TIC502 Slave
system function. When using only one TIC102 Slave or TIC502 Slave, all devices can be
automatically assigned to the components of the system functions with their factory
setting IP addresses.
When using the TIC501 and Axle Detector system functions, assignment of the 2D
LiDAR sensors can generally be made to the system components.
The following cases can be differentiated for assignment of the devices to the system
components:
• Device assignment for several TIC102 Slaves: To correctly assign the 2D LiDAR
sensors to the TIC102 Slaves used, you need the serial numbers that you recorded
before mounting (see chapter 4.2.1.1 Noting the serial numbers of the 2D LiDAR
sensors for several TIC102 Slaves). The identical IP addresses of the TIC102 Slave are
adjusted during device assignment.
• Device assignment for several TIC502 Slaves: To correctly assign the 2D LiDAR
sensors to the TIC102 Slaves used, you need the serial numbers that you recorded
before mounting (see chapter 4.2.1.1 Noting the serial numbers of the 2D LiDAR
sensors for several TIC102 Slaves). The identical IP addresses of the TIC502 Slave are
adjusted during device assignment.