ANNEX 9
8017768/12AX/2019-05-31|SICK
Subject to change without notice
OPERATING INSTRUCTIONS | TIC
9.1.3 TIC501 data sheet
TIC502 with separate evaluation unit
Vehicle classification, traffic counting
Vehicle class (various categorization systems with up to
30 classes)
Lane assignment
Confidence level for all vehicle data
Up to 4 lanes per LMS511 SE
> 99.8% (detection of 2 lanes overhead with an LMS511 SE)
Typ. 96% (for TLS 8+1 classes, detection of 2 lanes
overhead)
TEMS Info interface (TCP/IP interface)
TEMS Manager (HTTP configuration software)
Over the lane or on the side
Ambient operating temperature
* Protect the TIC502 from direct sunlight with a weather guard to
keep it from overheating.
Tab. 31: TIC501 data sheet
9.1.4 Excerpt from the LMS511 SE data sheet
Laser class 1 (IEC 60825-1 (2007-3)), eye-safe
80 m maximum
40 m maximum for objects with remission under 10%
5 x LED; 1 x 7 segment display
24 V DC (19.2 V DC ... 28.8 V DC)
22 W + 55 W heating (typical)
Ambient temperature
(operation)
Storage temperature range
Tab. 32: LMS511 SE data sheet