ANNEX 9
185
Subject to change without notice
OPERATING INSTRUCTIONS | TIC
9.1.3 TIC501 data sheet
TIC501
General advice
System part
TIC502 with separate evaluation unit
Features
Integrated application
Vehicle classification, traffic counting
Scanner version
1 scanner solution
Vehicle data
Vehicle class (various categorization systems with up to
30 classes)
Lane assignment
Confidence level for all vehicle data
Point clouds
Number of lanes covered
Up to 4 lanes per LMS511 SE
Performance
Counting accuracy
> 99.8% (detection of 2 lanes overhead with an LMS511 SE)
Classification accuracy
Typ. 96% (for TLS 8+1 classes, detection of 2 lanes
overhead)
Interfaces
Data log
TEMS Info interface (TCP/IP interface)
TEMS Manager (HTTP configuration software)
Mechanics/electronics
Mounting position
Over the lane or on the side
Weight
4.4 kg
Ambient operating temperature
–40 °C ... +60 °C *
* Protect the TIC502 from direct sunlight with a weather guard to
keep it from overheating.
Tab. 31: TIC501 data sheet
9.1.4 Excerpt from the LMS511 SE data sheet
LMS511 SE
Application
Outdoor
Light source
Infrared (λ = 905 nm)
Laser class
Laser class 1 (IEC 60825-1 (2007-3)), eye-safe
Aperture angle
190°
Scanning frequency
25 Hz ... 100 Hz
Sensing range
80 m maximum
40 m maximum for objects with remission under 10%
Statistical error
+/– 6 mm
Systematic error
+/– 25 mm
Ambient light immunity
70,000 lx
Optical indicators
5 x LED; 1 x 7 segment display
Voltage supply
24 V DC (19.2 V DC ... 28.8 V DC)
Power consumption
22 W + 55 W heating (typical)
Enclosure rating
IP 67, acc. to EN 60529
Weight
3.7 kg
Ambient temperature
(operation)
–40 °C ... +60 °C
Storage temperature range
–40 °C… +70 °C
Dimensions
160 mm x 155 mm x 185 mm
Tab. 32: LMS511 SE data sheet