5 ELECTRICAL INSTALLATION
8017768/12AX/2019-05-31|SICK
OPERATING INSTRUCTIONS | TIC
Subject to change without notice
5.5 Ethernet switch connection to the power supply
The cable for connecting the Ethernet switch to the voltage supply must be supplied by
the customer.
▸
Connect the Ethernet switch (which can be ordered as an accessory under part number
6043482) to the voltage supply as shown below.
Fig. 95: Electrical installation of Ethernet switch
5.6 Electrical installation of the LMS Axle
5.6.1 Connecting the LMS Axle to the TIC102
The LMS Axle is connected to the TIC102 in the lane in which axles are to be counted. The
connection is established via Ethernet cable.
Configuration for a lane with axle counting
The LMS Axle is connected to the TIC102 Master in series for configuration of a lane with
additional axle counting.
The two devices must be supplied separately with voltage.
Fig. 96: LMS Axle electrical installation – TIC102 (1 lane with axle counting)