Stopping raw data recording
1. After approximately 20 minutes, switch back to editing mode and open the detail
window for the system function.
2. Set the RawDataEnabled parameter to No.
Downloading raw data via FTP
Perform an FTP download to transfer the raw data from the /RawData directory on the
Traffic Controller.
1. Connect to the FTP server of the Traffic Controller using an FTP client (e.g., FileZilla).
2. Log in by entering client for the user name and client as the password.
Deleting raw data
Once the raw data has been downloaded from the /RawData directory on the Traffic
Controller, you must manually delete the data. Otherwise, the data will clog up the SSD by
taking up unnecessary storage capacity.
The raw data are not deleted automatically when you deactivate the function for recording
raw data.
8.3.5 Sensor component failures
In the event of a sensor component failure, the configuration continues running. However,
the profiling system is only operable to a limited extent (see also chapter 8.3.1.2 Fault
indicators at site level).
Once a configuration affected by errors has been stopped, the profiling system can no
longer be started.
The configuration can only be restarted once the fault has been resolved.
Important