FAULT DIAGNOSIS 8
8017768/12AX/2019-05-31|SICK
Subject to change without notice
OPERATING INSTRUCTIONS | TIC
8.3.1.1 Standardized visualization icons
In the live view, attention is drawn to errors and warnings by highlighting the system
components in different colors. The following color coding system applies:
• If a system component is shown in green in the live view, it is ready for operation.
• Yellow highlighting indicates a fault of the warning type.
• Red highlighting signals the presence of a device error.
You can narrow the problem down by right-clicking the system component’s red or yellow
icon. This opens a window containing further detailed information.
Green, yellow, or red icons are also used in the navigation tree to indicate whether the
system components and system functions are ready for operation.
A gray icon signals that the current status is unknown. This is the case during initialization
of the profiling system, for example.
8.3.1.2 Fault indicators at site level
Errors at site level are only shown in the menu bar.
• If the profiling system is only ready for operation to a limited extent, the Site workspace
is highlighted in red font.
• In addition, a red exclamation point appears.
• On the right-hand side, the following information message is displayed in red:
Configuration is running with error(s).
• A site error is displayed if there is an error (red icon) on at least one of the subordinate
levels.
A 2D LiDAR sensor outputs a contamination message. However, this does not affect
the operational readiness of the overall system in general. Consequently, the profiling
system remains ready for operation. Although the configuration is affected by the error,
it is still able to run.
• Warnings do not affect the site level.
Minor contamination of a 2D LiDAR sensors does not impair the operational readiness
of the profiling system.
Notes
Example
Example