8 FAULT DIAGNOSIS
8017768/12AX/2019-05-31|SICK
OPERATING INSTRUCTIONS | TIC
Subject to change without notice
8.3.1.3 Fault indicators at all subordinate levels
(navigation tree)
An error has occurred at a
subordinate level
▸ Check the live view or navigation
tree to see which component is
(navigation tree)
A warning has occurred at a
subordinate level
▸ Check the live view or navigation
tree to see which component is
yellow
Minor contamination on the
inspection window of the 2D
▸ Clean the inspection window of
the 2D LiDAR sensor when
red
Heavy contamination on the
inspection window of the 2D
▸ Clean the inspection window of
the 2D LiDAR sensor immediately.
yellow
Minor contamination on the
inspection window of the 2D
LiDAR sensor Inspection window
of the 2D LiDAR sensor is yellow
▸ Clean the inspection window of
the 2D LiDAR sensor.
red
Heavy contamination on the
inspection window of the 2D
▸ Clean the inspection window of
the 2D LiDAR sensor.
No supply voltage to the 2D
LiDAR sensor or voltage is too
▸ Check the voltage supply.
Ethernet connection to the 2D
LiDAR sensor interrupted.
▸ Check the Ethernet connection.
2D LiDAR sensor heater not
connected or temperature too
▸ Check the connection of the
heater.
2D LiDAR sensor defective.
▸ Note the fault indicator on the 2D
LiDAR sensor’s 7-segment display.
System functions without devices
* The icon is green when the system function is running properly.
A red icon indicates that system functions have not been linked correctly, for example.
Insufficient memory available
on the hard drive.
▸ Check the hard drive’s storage
capacity.
Directory not present on hard
drive
Hard drive not available