Functional Description of the Connectors/Interfaces
:
48 Hardware Description CNC 0610510/12 CNC 61.00
8.2.8 X20 - Motor Connector
X 4 pole Power CombiCon
Requirements to the motor cable:
The maximum admissible length of the motor cable is 100m. The capacity must not
exceed 5.2nF.
Example: If the cable capacity is 0.26nF per meter, the maximum admissible length
of the motor cable is 20m.
Pin Designation
1 motor phase U
2 motor phase V
3 motor phase W
4PE
L
Please refer to the documentation „Unit Assembly Complying EMC“
for detailed information about motor connection and grounding.
Warning
The maximum cable capacity is 5.2 nF.
The maximum cable length is 100m.