EasyManuals Logo

SIEB & MEYER CNC 61.00 User Manual

Default Icon
101 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #91 background imageLoading...
Page #91 background image
:
Option Modules
CNC 61.00 Hardware Description CNC 0610510/12 91
10.3.5 X13/X14 - Two Analog Inputs (12 bits)
This option provides two independent analog inputs with a resolution of 12 bits (11
bits plus sign), which can be used in the software (application program).
X13 - Analog Input 1/2
X 9-pole female Submin D connector
X Input resistance approx. 5 k
X Input voltage from -10 V to +10 V (reference ground)
X14 - Analog Input 2
X 9-pole female Submin D connector
Software (Example)
The analog inputs can be addressed with four system variables.
T_ACT [-2048..2047], T_ACT2 [-2048..2047]
The analog input values are mapped on these parameters. –10 volts at the input cor-
respond to T_ACT=-2048; +10 volts at the input correspond to T_ACT=+2047.
T_Offset [-2048..2047], T_Offset2 [-2048..2047]
These parameters define the offsets for both analog inputs. A deviation to the zero
point of the analog input value can be compensated by entering the actual converter
value (T_ACTx of the unloaded inputs) into this parameter.
Pin I/O Function
1 I analog input 1
2 I analog input 2
3
4
5
6
7
8
9GND
Pin I/O Function
1 I analog input 2
2
3
4
5
6
7
8
9GND
1
5
6
9
1
5
6
9

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SIEB & MEYER CNC 61.00 and is the answer not in the manual?

SIEB & MEYER CNC 61.00 Specifications

General IconGeneral
BrandSIEB & MEYER
ModelCNC 61.00
CategoryController
LanguageEnglish