EasyManua.ls Logo

Siemens MICROMASTER 440 - Page 120

Siemens MICROMASTER 440
312 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3 Functions Issue 10/06
MICROMASTER 440 Operating Instructions
120 6SE6400-5AW00-0BP0
BI: Fct digital output 1
Defines the source for digital output 1.
NOTE
The brake relay can also be controlled
from another digital output (if this is
available) or using a distributed I/O
module. Analog to DOUT 1, it should
be guaranteed that the I/Os are
controlled by the status bit “MHB
active”.
Inverting digital
outputs
This parameter allows the signals
to be output to be inverted.
Frequent settings:
52.0 Ready to power-up 0 Closed
52.1 Ready 0 Closed
52.2 Drive operational 0 Closed
52.3 Fault present 0 Closed
52.4 OFF2 active (present) 1 Closed
52.5 OFF3 active (present) 1 Closed
52.6 Power-on inhibit active (present) 0 Closed
52.7 Alarm active (present) 0 Closed
52.8 Deviation, setpoint/actual value 1 Closed
52.9 PZD / PLC control 0 Closed
52.A Maximum frequency reached 0 Closed
52.B Alarm: Motor current limit 1 Closed
52.C Motor holding brake active 0 Closed
52.D Motor overload 1 Closed
52.E Motor dir. of rotation, clockwise 0 Closed
52.F Frequency inverter overload 1 Closed
53.0 DC brake active 0 Closed
53.1 Actual freq. f_act > P2167 (f_off) 0 Closed
:
:
(52:3)
BI: Fct. of DOUT 1
P0731.C
-1
0
1
Invert DOUTs
0 ... 7
P0748 (0)
CO/BO: State DOUTs
r0747
r0747
Kl.20
Kl.18
.0
Function
xxxx.y
rxxxx.y
P0731 = xxxx.y
DOUT channel
Relay :
DC 30 V / 5 A
AC 250 V / 2 A
Kl.28
Kl.9
int. 24 V
max. 100 mA
NO
COM
NC
Kl.19
or
Text
- max. opening / closing time
5 / 10 ms
Holding brake release delay (entered in s)
Defines the time interval during which the frequency inverter runs with the min. frequency
p1080 after magnetizing, before the ramp-up starts.
P1216 brake opening time + relay opening time
Holding time after ramp-down (entered in s)
Defines time for which inverter runs at minimum frequency (p1080) after ramping down.
P1217 brake closing time + relay closing time
p1217 = ...
1.0 s
p1216 = ...
1.0 s
0
52.3
P0731=52.C
P0748 = 0