3 Functions Issue 10/06
MICROMASTER 440 Operating Instructions
200 6SE6400-5AW00-0BP0
In order that the motor can immediately establish a torque after an ON
command, the magnetizing time P0346, determined with the quick
commissioning, may not be reset. This is the reason that parameter P0346
should be checked for the weight equalization.
Typical magnetizing times for 4-pole 1LA7 motors are:
0.12 kW 50 ms 7.50 kW 300 ms
1.50 kW 100 ms 55.0 kW 700 ms
5.50 kW 250 ms
The min. frequency P1080 should approximately correspond to the rated
motor slip (P1080
r0330[Hz])
In addition, the voltage boost should be adapted:
V/f mode (P1300 = 0 ... 3)
- constant voltage boost P1310 90 % (empirical value)
- voltage boost when accelerating
P1311
50 % (empirical value)
SLVC mode (P1300 = 20)
- constant torque boost P1610 90 % (empirical value)
- torque boost when accelerating
P1611
50 % (empirical value)
¾ Connecting-up the motor holding brake control
Directly connected to the 1
st
relay output
Motor with
motor
holding brake
COM
NC
NO
COM
NC
NO
COM
NO
20
18
19
25
23
24
22
21
CPU
MICROMASTER 440
M
3
~
=
Fig. 3-70 Direct motor holding brake connection