3  Functions  Issue 10/06 
  MICROMASTER 440      Operating Instructions 
200  6SE6400-5AW00-0BP0 
♦  In order that the motor can immediately establish a torque after an ON 
command, the magnetizing time P0346, determined with the quick 
commissioning, may not be reset. This is the reason that parameter P0346 
should be checked for the weight equalization.  
Typical magnetizing times for 4-pole 1LA7 motors are: 
  0.12 kW  50 ms  7.50 kW  300 ms 
  1.50 kW  100 ms  55.0 kW  700 ms 
  5.50 kW  250 ms 
♦  The min. frequency P1080 should approximately correspond to the rated 
motor slip (P1080 
≈ r0330[Hz]) 
♦  In addition, the voltage boost should be adapted: 
−  V/f mode (P1300 = 0 ... 3) 
-  constant voltage boost   P1310 ≈ 90 %  (empirical value) 
-  voltage boost when accelerating 
 P1311 
≈ 50 %  (empirical value) 
−  SLVC mode (P1300 = 20) 
-  constant torque boost   P1610 ≈ 90 %  (empirical value) 
-  torque boost when accelerating 
 P1611 
≈ 50 %  (empirical value) 
¾  Connecting-up the motor holding brake control 
♦  Directly connected to the 1
st
 relay output 
Motor with
motor
holding brake
COM
NC
NO
COM
NC
NO
COM
NO
20
18
19
25
23
24
22
21
CPU
MICROMASTER 440
M
3
~
=
 
Fig. 3-70  Direct motor holding brake connection