6 Options Issue 10/06
MICROMASTER 440 Operating Instructions
274 6SE6400-5AW00-0BP0
6.2 Inverter-dependent options
Frame Sizes A to F
¾ EMC filter. Class A
¾ EMC filter. Class B
¾ Additional EMC filter. Class B
¾ Low leakage Class B filter
¾ Line commutating choke
¾ Output choke
¾ Gland plate
¾ LC filter
CAUTION
When using output reactors and LC filters, operation up to a pulse frequency of
4 kHz only is permitted. Please ensure that the automatic pulse frequency
reductions are also deactivated. Mandatory parameter settings when using an
output reactor: P1800 = 4 kHz , P0290 = 0 or 1.
Frame Sizes FX and GX
¾ Line commutating choke
¾ EMC filter. Class A (power commutating choke required)
¾ LC filter
CAUTION
When using output reactors and LC filters, operation up to a pulse frequency of
4 kHz only is permitted. Please ensure that the automatic pulse frequency
reductions are also deactivated. Mandatory parameter settings when using an
output reactor: P1800 = 4 kHz , P0290 = 0 or 1.