EasyManuals Logo

Siemens SIMADYN D User Manual

Siemens SIMADYN D
534 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #311 background imageLoading...
Page #311 background image
Communications configuring
3-222 System- and communication configuring D7-SYS - SIMADYN D
Edition 12.2003
The following is still valid: Parameter d999 is optional to identify the
software version and release of standard software packages.
d999 Software Examples
1AB Angular synchronism, version A.Bx
(x is used to number compatible versions)
120
SPA440 V2.0x
123
SPA440 V2.3x
2AB Axial winder, version A.Bx
221
SPW420 V2.1x
3AB
Cross-cutter/closed-loop shears control,
version A.Bx
310
SPS450 V1.0x
If the device identification is not successful, then an attempt is made to
identify the known devices types.
If “DRIVE Monitor“ recognizes a different software (d999), the “Create
database” option is listed in the “Device identification” dialog box. This
means that a specific database can be set-up.
3.19.1.5 Units and unit texts
In order that you can assign units (physical quantities) to an input or
output, you must configure a text string for the block I/O from the table
below.
Physical quantity Units Text string to be configured
Length Meters m
Millimeters mm
Kilometers km
Micrometers um
Surface Square meters
Square millimeters mm2
Square kilometers km2
Volume Cubic meters
Liters l
Time Seconds s
Minutes min
Hours h
Days d
Milliseconds ms
Microseconds us
Force Newton N
Kilo newtons kN
Mega newtons MN
Pressure Pascal Pa
Kilopascal kPa
Millibar mbar
Bar bar

Table of Contents

Other manuals for Siemens SIMADYN D

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMADYN D and is the answer not in the manual?

Siemens SIMADYN D Specifications

General IconGeneral
BrandSiemens
ModelSIMADYN D
CategoryControl Systems
LanguageEnglish

Related product manuals