EasyManua.ls Logo

Siemens SIMADYN D User Manual

Siemens SIMADYN D
534 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
s
Contents, Foreword
In just a few steps to the first
project
Systemsoftware
Communications configuring
Changeover from STRUC V4.x
to D7-SYS
Closed-loop thristor current
control
Index
System- and communication
configuring D7-SYS
Manual
SIMADYN D
Edition 12.2003

Table of Contents

Other manuals for Siemens SIMADYN D

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMADYN D and is the answer not in the manual?

Siemens SIMADYN D Specifications

General IconGeneral
ManufacturerSiemens
Communication ProtocolsPROFIBUS
ApplicationsIndustrial automation, process control
Operating SystemReal-time operating system
Programming LanguagesStructured Text (ST), Function Block Diagram (FBD), Ladder Diagram (LD)
I/O ModulesDigital and analog I/O modules
Power Supply24V DC
Operating Temperature0°C to 60°C
Relative Humidity5% to 95% (non-condensing)
Vibration ResistanceComplies with industrial standards (e.g., IEC 60068-2-6)
Shock ResistanceComplies with industrial standards (e.g., IEC 60068-2-27)

Summary

Foreword

Purpose of this Manual

Explains the manual's purpose and scope for understanding STEP 7 automation software.

Additional support

Provides contact information and hotline details for questions not answered in the manual.

Guide

Recommends a usage strategy for first-time users to understand terminology and procedures.

1 In just a few steps to the first project

1.1 Prerequisites

Describes the necessary software and hardware components for initial project setup.

1.2 Creating a new project

Details the steps for creating a new project in SIMATIC Manager.

1.3 Defining the hardware

Explains how to configure hardware components in HW Config, including subrack and CPU.

1.4 Generating a CFC chart

Covers creating new CFC charts and inserting function blocks for program logic.

1.5 Testing, compiling and downloading the project

Outlines the process of checking project consistency and downloading to the CPU.

1.6 Testing the user project

Describes how to test and modify the configured project online in test mode.

2 Systemsoftware

2.1 Configuring

Provides instructions and requirements for configuring SIMADYN D hardware and software.

2.2 Function description and user instructions

Covers function descriptions, error handling, and background processing related to system software.

2.3 System chart @SIMD

Explains the system chart for diagnostics and monitoring of hardware and software status.

3 Communications configuring

3.1 Introduction

Introduces fundamental concepts for establishing communications, utilities, and interfaces.

3.4 Industrial Ethernet coupling (SINEC H1)

Explains SINEC H1 communication versions (Layer 2, 4, 7) and bus node requirements.

3.5 PROFIBUS DP coupling

Covers hardware, software, characteristics, and configuration of PROFIBUS DP coupling.

3.13 USS master coupling

Covers the USS master coupling's general features, mode of operation, and hardware structure.

3.17 SIMOLINK drive coupling

Covers SIMOLINK drive coupling basics, applications, features, and configurations.

3.27 Communications with SIMATIC Operator Panels

Explains coupling SIMADYN D to SIMATIC OP7 using configuring software example.

3.29 Communications with WinCC (SINEC H1)

Explains how to couple WinCC to SIMADYN D via SINEC H1 coupling using example software.

4 Changeover from STRUC V4.x to D7-SYS

4.1 Function blocks

Details changes in function blocks, naming conventions, and data types between STRUC V4.x and D7-SYS.

4.3 Hardware differences

Describes the differences in hardware components between STRUC V4.x and D7-SYS.

4.5 Configuring

Compares configuring tools and installation/de-installation procedures between STRUC V4.x and D7-SYS.

4.6 Configuring, step by step

Provides an overview of essential working steps under STEP7 for configuring.

4.7 V4.x terminology which is replaced by D7-SYS terminology

Compares terminology used in SIMADYN D environment for Version 4.x with D7-SYS.

5 Closed-loop thyristor current control

5.1 Overview

Provides an overview of the closed-loop thyristor current control, its validity, and included functions.

5.2 Function description

Describes various converter-specific function blocks like PA6, EMF, SOL, CAV, CSP, CPC, CPI, PC6, FCS.

5.3 Commissioning

Details the necessary measuring equipment, preparatory work, and calibration steps for commissioning.

5.4 Special features/issues

Covers operation with 60 Hz line supplies and handling unstable line supplies.

5.5 Interfaces to the power electronics

Explains connections to power electronics, including SITOR sets and cabinets.

Related product manuals