Technical specifications
8.3 Current/power requirements and power supply
SIMATIC IPC627E
Operating Instructions, 12/2018, A5E44297201-AA
113
8.3.2 Technical specifications AC power supply (AC)
Degree of protection
IP 20 (in installed state)
Protection class
VDE 0106
Note
The power supply contains an active PFC (Power Factor Correction) circuit to conform to the
EMC guidelines.
Uninterruptible AC power
systems (UPS) must supply a sinusoidal output voltage in the
normal and buffered mode when used with SIMATIC PCs with an active PFC.
UPS characteristics are described and classified in the standards EN 50091
-3 and IEC
62040
-3. Devices with sinusoidal output voltage in the normal and buffered mode are
identified with the classification "VFI
-SS-...." or "VI-SS-....".
Power supply characteristics
AC power supply
Input data
Voltage Nominal 100 - 240 V AC (-15% / +10%), wide
range
Frequency Nominal 50-60 Hz (min. 47 - max. 63 Hz), sinus-
oidal
Continuous current
Max. 1.7 A
Starting current (load-independent)
Up to 50 A for 1 ms
Active power
176 W
Apparent power
190 VA
Output data
Voltages
+12 V / 12.5 A
Secondary power output
Max. 150 W

Table of Contents

Other manuals for Siemens SIMATIC IPC627E

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC IPC627E and is the answer not in the manual?

Siemens SIMATIC IPC627E Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC IPC627E
CategoryIndustrial PC
LanguageEnglish

Related product manuals