Technical support
B.2 Troubleshooting
SIMATIC IPC627E
154 Operating Instructions, 12/2018, A5E44297201-AA
B.2.3 Problems with RAID systems
The RAID software reports the
following errors:
• The RAID plug-in failed to
load, because the drive is
not installed.
• The Serial ATA plug-in
failed to load, because the
driver is not installed cor-
rectly.
• The Intel
®
Storage Con-
sole was unable to load a
page for the following rea-
son:
– A plug-in did not pro-
vide a page for the se-
lected device
– A plug-in failed to load
RAID is not activated The messages have no negative effect on the opera-
tion of the device and can be ignored.
Acknowledge the messages.
RAID is activated Install the software again with the help of the sup-
plied data storage medium.
B.2.4 Problems when using expansion cards
The device crashes
during startup.
• I/O addresses are assigned
twice.
• Hardware interrupts and/or
DMA channels are assigned
twice
• Signal frequencies or signal
levels are not adhered to
• Different pin assignment
Check your computer configuration:
• If the computer configuration corresponds to the delivery
condition, contact your technical support team.
• In the case of a change in the configuration, restore the
delivery condition. To do this, remove the expansion card
and restart the device. If the error no longer occurs, the ex-
pansion card was the cause of the fault. Replace this with a
Siemens expansion card or contact the supplier of the ex-
pansion card.
If the device still crashes, contact your technical support team.