Expanding and assigning parameters to the device
6.4 Drives
SIMATIC IPC627E
Operating Instructions, 12/2018, A5E44297201-AA
87
6.4.5 Replacing M.2 NVMe SSD
Note
An M.2 NVMe SSD cannot be operating in a RAID
-System.
Requirements
Note
Observe the ESD directives
Observe the ESD directives.
M.2 NVMe SSDs with an length of up to 110 mm
Phillips screwdriver P1
The drive bay module and the power supply are removed, see Replacing the bus board
(Page 100)
Procedure
1. Place the bus board on a suitable surface so that it lies flat and plane.
2. Remove the marked screw.
3. Lift the M.2 NVMe SSD slightly as shown and pull it out of the direct connector socket.
4. Lay the thermal pad on the bus board in such a manner that it is covered completely by
the M.2 NVMe SSD after the SSD's installation.

Table of Contents