Technical specifications
8.6 BIOS description
SIMATIC IPC847D
Operating Instructions, 01/2014, A5E32997454-AA
185
Display
(hex)
Meaning
Description
Remedy
76H PEI_SB_REG_INIT South Bridge Early Initial Initialization of the South
bridge
Service case
77H PEI_PCIE_TRAINING PCIE Training Training phase of the PCIE
device
Service case
79H
PEI_SMBUS_INIT
SMBUS Early Initial
Initialization of the SM Bus
Service case
41H DXE_SB_SPI_INIT South bridge SPI initial Initialization of the Serial
Peripheral Interface in the
South Bridge
Service case
42H DXE_CF9_RESET Setup Reset service,
DXE_CF9Reset
Setup Reset service Service case
43H DXE_SB_SERIAL_GPIO_INIT South bridge Serial GPIO
initial,
DXE_SB_SerialGPIO_INIT
Initializations of the serial
GPIO
Service case
44H DXE_SMMACCESS Setup SMM ACCESS
service
Setup SMM access service Service case
45H DXE_NB_INIT North bridge Middle initial Initialization of the North
Bridge
Service case
46H DXE_SIO_INIT Super I/O DXE initial Initialization of the Super IO Service case
47H DXE_LEGACY_REGION Setup Legacy Region
service,
DXE_LegacyRegion
Setup service Legacy
region
Service case
48H DXE_SB_INIT South Bridge Middle Initial Initialization of the South
Bridge
Service case
49H
DXE_IDENTIFY_FLASH_DEVICE
Identify Flash device
Identify FLASH type
Service case
4AH DXE_FTW_INIT Fault Tolerant Write
verification
Checking of the write fault
tolerance
Service case
4BH DXE_VARIABLE_INIT Variable Service Initial Initialization of the variable
service
Service case
4CH DXE_VARIABLE_INIT_FAIL Fail to initial Variable
Service
Failure to initialize the
variable service
Service case
26H BDS_CONNECT_LEGACY_ROM Dispatch option ROMs Callup of the Legacy Option
ROMs
Service case
27H BDS_ENUMERATE_ALL_BOOT_OP
TION
Get boot device information Determine the Boot Device
information
Service case
28H
BDS_END_OF_BOOT_SELECTION
End of boot selection
Boot selection terminated
Service case
29H
BDS_ENTER_SETUP
Enter Setup Menu
Callup into SETUP
Service case
2AH
BDS_ENTER_BOOT_MANAGER
Enter Boot manager
Callup Boot Manager
Service case
2BH
BDS_BOOT_DEVICE_SELECT
Try to boot system to OS
Booting of the OS
Service case
2CH BDS_EFI64_SHADOW_ALL_LEGAC
Y_ROM
Shadow Misc Option ROM Copying the Legacy Option
ROMs into RAM
Service case
2DH BDS_ACPI_S3SAVE Save S3 resume required
data in RAM
Make available for operating
state S3 RAM
Service case
2EH BDS_READY_TO_BOOT_EVENT Last Chipset initial before
boot to OS
Initialization of the last
chipset before the OS Boot
Service case
2FH
BDS_GO_LEGACY_BOOT
Start to boot Legacy OS
Boot Legacy OS
Service case
30H
BDS_GO_UEFI_BOOT
Start to boot UEFI OS
Boot UEFI OS
Service case