Mobile data storage units   
5.3 MDS D100 
  MOBY D 
104  System Manual, 01/2010, J31069-D0147-A6-7618 
5.3.5  Technical data 
Table 5- 4  Technical data for MDS D100 
Memory size  128 bytes 
Memory configuration 
  Serial number 
  Configuration memory 
  Application memory 
 
  8 bytes (fixed code) 
  8 bytes 
  112 bytes 
Storage technology  EEPROM 
Memory organization  EEPROM 128 bytes gross 
112 bytes net capacity 
When using the OPT area, 16 bytes of it must be 
subtracted in 4 byte blocks 
Protocol  according to ISO 15693 
Data retention (at +40 °C)  10 years 
MTBF (at +40 °C)  2 x 10
6
 hours 
Read cycles  Unlimited 
Write cycles, typical  1 000 000 
Write cycles, min.  100 000 
Read/write distance (S
g
)  See Chapter . 
Distance from metal  min. 20 mm (approx. 30% reduction of the field data) 
Multitag capability  Yes 
Power supply  Inductive power transmission (without battery) 
Degree of protection to EN 60529  IP68 
Vibration  ISO 10373/ISO 7810 
Torsion and bending load  ISO 10373/ISO 7816-1 
Mechanical design 
  Color 
  Material 
  Dimensions (L x W x H) in mm 
Laminated plastic card, printable on both sides 
  White/petrol 
  PC 
  85.6 (±0.2) x 54 (±0.2) x 0.9 (±0.05) 
Fixing  Adhesive, fixing pocket 
Ambient temperature 
  During operation 
  Transport and storage 
 
  -25 °C to +80 °C 
  -25 °C to +80 °C 
Weight, approx.  5 g