Mobile data storage units
5.3 MDS D100
MOBY D
104 System Manual, 01/2010, J31069-D0147-A6-7618
5.3.5 Technical data
Table 5- 4 Technical data for MDS D100
Memory size 128 bytes
Memory configuration
Serial number
Configuration memory
Application memory
8 bytes (fixed code)
8 bytes
112 bytes
Storage technology EEPROM
Memory organization EEPROM 128 bytes gross
112 bytes net capacity
When using the OPT area, 16 bytes of it must be
subtracted in 4 byte blocks
Protocol according to ISO 15693
Data retention (at +40 °C) 10 years
MTBF (at +40 °C) 2 x 10
6
hours
Read cycles Unlimited
Write cycles, typical 1 000 000
Write cycles, min. 100 000
Read/write distance (S
g
) See Chapter .
Distance from metal min. 20 mm (approx. 30% reduction of the field data)
Multitag capability Yes
Power supply Inductive power transmission (without battery)
Degree of protection to EN 60529 IP68
Vibration ISO 10373/ISO 7810
Torsion and bending load ISO 10373/ISO 7816-1
Mechanical design
Color
Material
Dimensions (L x W x H) in mm
Laminated plastic card, printable on both sides
White/petrol
PC
85.6 (±0.2) x 54 (±0.2) x 0.9 (±0.05)
Fixing Adhesive, fixing pocket
Ambient temperature
During operation
Transport and storage
-25 °C to +80 °C
-25 °C to +80 °C
Weight, approx. 5 g