162  System Manual, 01/2010, J31069-D0147-A6-7618 
6.4.3  Technical data 
Table 6- 11  Technical data for SLG D12 
Inductive interface to the MDS   
Transmission frequency  13.56 MHz 
Transponders supported  Transponders according to ISO 15693 and I-Code1 
Serial interface to the user  RS 232 
Transmission protocol  Asynchronous 8 bit 
Data transmission rate  9600 baud to 38.4 Kbaud (adjustable) 
Data backup  CRC 16 
Transmit power  1 W 
Write/read distances SLG - MDS  160 mm typically (see field data) 
Software functions  Read, write, initialize MDS, access rights, multitag 
Programming  Windows 9x, 2000, NT and XP with 32 bit DLL available 
Multitag  Yes 
Anti-collision speed  approx. 20 labels/s simultaneously identifiable 
Power supply 
  Rated value 
  Permissible range 
 
 
'&9
 
 
'&9s8/RQO\
'&99
Current consumption 
  Operation 
  Inrush current, momentary 
 
  150 mA 
  600 mA 
Cable length SLG – PC with RS 232  30 m 
Digital inputs/outputs  None 
Enclosure dimensions (L x W x H) in 
mm 
160 x 80 x 40 (without connector) 
Color  Anthracite 
Material  Plastic PA 12 
Connector 
  V24 interface 
  Power supply 
 
  9-pin Sub-D connector (male) 
  4-pin M12 connector (male) 
Mounting  2 x M5 screws 
Ambient temperature 
  Operation 
  Transport and storage 
 
  -25 °C to +55 °C 
  -25 °C to +70 °C 
MTBF  2.0 x 10 
5
 hours 
Degree of protection according to EN 
60529 
IP65 (UL: for indoor use only) 
Shock resistant according to EN 
60721-3-7 Class 7M2 
Total shock response spectrum Type II 
30 g 
Vibration according to EN 60721-3-7 
Class 7M2 