Planning the MOBY D system 
  4.1 Fundamentals of application planning 
MOBY D 
System Manual, 01/2010, J31069-D0147-A6-7618 
31 
4.1.6  Communication between ASM, write/read device and MDS 
Communication with the SLG is asynchronous with a transmission rate of  
●  19.2 Kbaud with SLG D11S/SLG D12S 
●  38.4 Kbaud with SLG D11/SLG D12 
●  115.2 Kbaud with SLG D10/SLG D10S 
Table 4- 1  Data transmission rate 
  with MDS D1xx/MDS D2xx/MDS D3xx  with MDS D4xx 
reading  ≥ 2.5 ms/byte 
Writing  ≥ 9.5 ms/byte 
 
≤ 2.5 ms/byte 
 
Table 4- 2  Transfer time for UID number (8 bytes) 
SLG  Transmission time 
SLG D11S/SLG D12S  60 ms (at 19.2 Kbaud) 
SLG D11/SLG D12  60 ms (at 38.4 Kbaud) 
SLG D10/SLG D10S   50 ms (at 115.2 Kbaud) 
 
Table 4- 3  Traversing speed for SLG D1x / ANT Dx (with one transponder in the field) 
  SLG D10  SLG D11  SLG 
D12 
SLG D10S  SLG D11S  SLG 
D12S 
 ANT 
D10* 
ANT 
D6 
ANT 
D5 
ANT 
D2 
ANT 
D5 
 ANT 
D10* 
ANT 
D6 
ANT 
D5 
ANT 
D2 
ANT 
D5 
 
UID number  
(8 bytes) 
≤ 15  ≤ 8.0  ≤ 5.0  ≤ 1.2  ≤ 3.5  ≤ 2.5  ≤ 6.0  ≤ 3.8  ≤ 2.0  ≤ 0.4  ≤ 1.0  ≤ 0.8 
ISO tags, e.g. MDS D100 
Read  
(with 4 bytes  
user data / 
1 block) 
≤ 10  ≤ 6.0  ≤ 3.5  ≤ 1.2  ≤ 1.6  ≤ 1.2  ≤ 6.5  ≤ 4.0  ≤ 2.2  ≤ 0.4  ≤ 3.0  ≤ 1.4 
Write  
(with 4 bytes  
user data / 
1 block) 
≤ 9  ≤ 5.5  ≤ 3.0  ≤ 0.2  ≤ 1.2  ≤ 1.0  ≤ 5.5  ≤ 3.4  ≤ 1.8  ≤ 0.3  ≤ 2.8  ≤ 1.2 
Read  
(with 112 
bytes of 
complete user 
data) 
≤ 7.5  ≤ 4.0  ≤ 2.4  ≤ 0.4  ≤ 1.4  ≤ 0.8  ≤ 5.0  ≤ 3.0  ≤ 1.6  ≤ 0.2  ≤ 2.2  ≤ 1.0 
Write  
(with 112 
bytes of 
complete user 
data) 
≤ 2.0  ≤ 1.0  ≤ 0.6  ≤ 0.1  ≤ 0.4  ≤ 0.2  ≤ 2.0  ≤ 1.0  ≤ 0.6  ≤ 0.1  ≤ 0.5  ≤ 0.2 
All values in the table in m/s 
* Traversing speed in lateral direction as for SLG D10 ANT D5/SLG D10S ANT D5