Mobile data storage units 
  5.12 MDS D428 
MOBY D 
System Manual, 01/2010, J31069-D0147-A6-7618 
141 
5.12.3  Application example of MDS D428 
0DLQILHOG
0RWRUEORFN
&RQYH\RUGLUHFWLRQ
0'6'
6/*
 
Figure 5-26  Application example 
Table 5- 19  Field data MDS D428 - MOBY D-SLG 
  SLG D10/D10S  
ANT D5 
SLG D11/D11S 
ANT D5 
SLG D12/D12S 
Operating distance (Sa)  0…120  0…70  0…40 
Limit distance (Sg)  160  100  60 
Transmission window 
(L
x
/L
y
) 
∅ 300  ∅ 280  100 / 60 
Minimum distance from 
MDS to MDS 
≥ 800  ≥ 800  ≥ 300 
All values are in mm