Previous versions 
  C.2 Discontinued SLG with ANT D5 
MOBY D 
System Manual, 01/2010, J31069-D0147-A6-7618 
319 
C.2.3  SLG D11 ANT D5 (MLFB 6GT2601-0AC00) 
Application area 
SLG D11 ANT D5 is a write/read device in the mid performance range with a serial interface 
and a separate antenna which has been specially designed for warehouses, logistics and 
distribution. It is designed for a range of up to 380 mm (depending on the label).  
The write/read device is equipped with a serial RS 232 interface which supports 
communication with the PC or non-Siemens PLCs. 
For fast and easy programming, a C library is available to the user that supports the use of 
Windows 9x, 2000, NT and XP.  
SLG D11 ANT D5 has multitag capability. 
 
Figure C-13  Write/read device SLG D11 ANT D5 
Ordering data 
Table C- 10  Ordering data for SLG D11 ANT D5 
  Order no. 
SLG D11 ANT D5 write/read device basic unit 
with RS 232 serial interface for standard PC,  
with separate antenna 
6GT2601-0AC00 
 
Accessories: 
Spacer kit for ANT D5 
Wide-range power supply unit for SIMATIC RF 
systems (100 - 240 V AC / 24 V DC / 3 A) with 2 m 
connecting cable and country-specific plug. 
  EU 
  UK 
  US 
Cables and connectors 
 
6GT2690-0AB00 
 
 
 
  6GT2898-0AA00 
  6GT2898-0AA10 
  6GT2898-0AA20 
see Chapter 
 Planning the MOBY D system