Mobile data storage units
5.6 MDS D160
MOBY D
120 System Manual, 01/2010, J31069-D0147-A6-7618
-25 °C to +85 °C Permanent
+125 °C
for 1000 hours
(20% reduction in the
limit distance)
+175 °C
1)
500 x for 10 minutes
During operation
+220 °C
1)
1 x for 30 seconds
Ambient temperature
Transport and
storage
-25 °C to +100 °C
Weight, approx. 1 g
1)
No processing possible from +140 °C upwards
Note
Regeneration time for the MDS D160 between wash cycles must be at least 24 hours
It is recommended that a test is performed in critical applications.
5.6.5 Dimension drawing
ss
Dimensions in mm
Figure 5-14 Dimension drawing of MDS D160