9.3.3 Basic module - Requirements for operation of ASM 473
The following table indicates the status of the ET 200X basic module of 10/2002. The
functionality of new basic modules is stored in HW Config of the SIMATIC Manager.
Table 9- 5 Requirements for operation of ASM 473
Order number of the ET 200X
basic module
For operation with ASM 473
(6GT2002-0HA00)
*
For operation with ASM 473
PARAM (6GT2002-0HA10)
6ES7141-1BF00-0XB0 no no
6ES7141-1BF00-0AB0 Yes Yes
6ES7141-1BF01-0XB0 no no
6ES7141-1BF10-0XB0 no no
6ES7141-1BF11-0XB0 Yes Yes
6ES7141-1BF40-0AB0 Yes Yes
6ES7142-1BD10-0XB0 no no
6ES7142-1BD11-0XB0 no no
6ES7142-1BD20-0XB0 no no
6ES7142-1BD21-0XB0 Yes Yes
6ES7142-1BD22-0XB0 no Yes
**
6ES7143-1BF00-0AB0 Yes Yes
6ES7143-1BF00-0XB0 Yes Yes
6ES7147-1AA00-0XB0 no no
6ES7147-1AA01-0XB0 no Yes
* Discontinued
** Notes on operation:
In HW Config, please parameterize the module 6ES7142-1BD21-0XB0.