Table 11- 5  Error codes for ISO transponders 
Error code 
in HEX 
Explanation of error codes in the transponder response 
0x01  Command not supported (the request code was not recognized) 
0x02  Command not recognized (e.g. due to a format error) 
0x03  Option not supported 
0x0F  Unknown error 
0x10  Specified block does not exist 
0x11  Specified block is already disabled and cannot be disabled again 
0x12  Specified block is disabled, its contents cannot be changed 
0x13  Unsuccessful attempt to program the specified block 
0x14  Unsuccessful attempt to disable the specified block 
0xA0 - 
0xDF 
Error codes for user-specific commands 
All others  Reserved for future use 
11.2  Error messages and causes for MOBY D with ASM and FC/FB 45 
(direct MDS addressing) 
11.2.1  General errors 
Automation system switches to STOP 
●  OB 86 not programmed and a slave has failed. 
●  OB 122 not programmed and a slave has failed. 
The error does not occur until FC/FB 45 is called. 
●  The pointer Params_DB, command_DB or DAT_DB does not exist or is pointing to a non-
existent address area.