Alarm, error and system messages   
11.1 Error messages and causes for MOBY D in combination with the MDWAPI library 
  MOBY D 
280  System Manual, 01/2010, J31069-D0147-A6-7618 
11.1  Error messages and causes for MOBY D in combination with the 
MDWAPI library 
Table 11- 1  General errors 
Error code 
in HEX 
Cause, remedy 
0x00  OK: 
  Data/parameters read or saved without errors 
  Control command executed 
 
Table 11- 2  Transponder status 
Error code 
in HEX 
Cause, remedy 
0x01  No transponder: 
  No transponder within the detection field of the reader 
  Transponder in detection field has been switched to silent 
  Error in communication between reader and transponder. The reader can no longer 
detect the transponder. 
0x02  Invalid data: 
  CRC16 checksum error in the received data 
0x03  Write error: 
Plausibility test of written data failed: 
  Attempt to write to a read-only area 
  Distance between transponder and read antenna too large 
  Attempt to write during excessive ambient noise 
0x04  Address error: 
The requested data lie beyond the logical or physical address range of the transponder:
  The addresses lie outside the maximum address range of the transponder 
  The addresses lie outside the configured address range of the transponder 
0x05  Invalid transponder type: 
This command is not supported by this transponder: 
  Write or read attempt with a transponder 
  A specific command is not supported by the transponder. 
0x06  Read error: 
Plausibility test of read data failed: 
  Distance between transponder and read antenna too large 
  Attempt to read during excessive ambient noise