Table 5- 15  Technical data MDS D324 
Memory size  1024 bytes 
Memory configuration 
  Serial number 
  Configuration memory 
  Manufacturer data 
 
  8 bytes (fixed code) 
  1008 bytes 
  8 bytes 
Storage technology  EEPROM 
Memory organization  1024 EEPROM/gross  
992 net capacity 
When using the OPT area, 16 bytes of it must be 
subtracted in 4 byte blocks 
Protocol  according to ISO 15693 
Data retention (at +40 °C)  10 years 
MTBF (at +40 °C)  ≥ 1.5 x 10
6
 hours 
Read cycles  Unlimited 
Write cycles, typical  1 000 000 
Write cycles, min.  100 000 
Read/write distance (S
g
)  See Chapter  
Distance from metal  Min. 25 mm (approx. 30% reduction of the field data) 
Multitag capability  Yes 
Anti-collision speed  Approx. 20 transponders/s simultaneously 
identifiable 
Power supply  Inductive power transmission  
(without battery) 
Degree of protection to EN 60529  IP67 
Shock resistant to EN 60721-3-7, Class 7M3 
total shock response spectrum, type II 
100 g 
Vibration-resistant to EN 60721-3-7, Class 
7M3 
20 g 
Torsion and bending load  Not permissible 
Enclosure 
  Dimensions (D x H) in mm 
  Color 
  Material 
 
  27(±-0,2) x 4(±0.2) 
  Black 
  Epoxy casting resin 
Fixing  Adhesive, M3 screw 
Tightening torque at +20 °C  ≤ 1 Nm 
(at high temperatures, the expansion coefficients of 
the materials used must be taken into account)