Write/read devices with RS422 interface   
7.5 SLG D12S (plug-in version) 
  MOBY D 
194  System Manual, 01/2010, J31069-D0147-A6-7618 
7.5  SLG D12S (plug-in version) 
7.5.1  Features 
 
SLG D12S (plug-in version)  Features 
Performance range  The SLG D12S (plug-in version) is a 
write/read device in the lower 
performance range with serial interface. 
Range  up to 160 mm 
Interface  RS422 serial interface 
8-pin M12 connector  for 
  Power supply 
  Data communication 
Communication  via interface modules to SIMATIC S7 or 
PROFIBUS DP-V1/PROFINET/Ethernet 
IP 
Connectable ASM 
  ASM 452 
  ASM 456 
  ASM 473 
  ASM 475 
  RF170C 
  RF180C 
  RF182C 
Antenna  integrated 
Programming options  e.g. via FB 45/FC 45 
High degree of 
protection 
IP67 
 
 
 
Multitag capability  no