EasyManua.ls Logo

Siemens SIMATIC MOBY D - Technical Data

Siemens SIMATIC MOBY D
350 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Mobile data storage units
5.7 MDS D165
MOBY D
122 System Manual, 01/2010, J31069-D0147-A6-7618
5.7.3 Technical data
Memory configuration
Serial number (UID)
Configuration memory
AFI/DSFID
Application memory
8 bytes (fixed code)
6 bytes
2 bytes
112 bytes
Storage technology EEPROM
Memory organization 4 bytes, block by block
Protocol according to ISO 15693
Data transmission rate
reading
writing
approx. 3.5 ms/byte
approx. 9.5 ms/byte
Multitag capability Yes
Data retention 10 years
Read cycles
Write cycles, min.
Unlimited
100 000
Recommended distance to metal 25 mm (approx. 30% reduction of the field data)
Power supply Inductive power transmission (without battery)
Typical read/write distance (Sg) See Chapter Field data (Page 33)
Degree of protection according to EN 60529 IP65
Dimensions
L x W (in mm)
Height
86 x 54
approx. 0.3 mm
Material
Top
Inlay
Antenna
Bottom
PET plastic (label material)
PET plastic (carrier material)
Aluminum
Double-sided transfer adhesive on silicon
paper
Color White
Mounting Single-sided adhesive (self-adhesive label)
Imprinting Yes, (heat transfer method)
Ambient temperature during operation
Storage temperature
-25 °C to +85 °C
+20 °C to +30 °C (the storage period is 2
years, determined by durability of the
adhesive)