6.2.3 Technical data
Table 6- 5 Technical data for SLG D10 basic unit
Inductive interface to the MDS
Transmission frequency 13.56 MHz
Transponders supported Transponders according to ISO 15693 and
I-Code1
Serial interface to the user RS 232 (RS 422 on request)
Transmission protocol Asynchronous 8 bit
Data transmission rate 9600 baud to 115.2 Kbaud
(adjustable)
Data backup CRC 16
Transmit power up to 10 W
Write/read distances SLG - MDS 650 mm typically (see field data)
Software functions Read, write, initialize MDS, access rights,
multitag
Programming Windows 9x, 2000, NT, XP with 32 bit DLL
available
Multitag Yes
Anti-collision speed approx. 20 labels/s simultaneously
identifiable
Power supply
Current consumption
Operation
Inrush current, momentary
up to 1.4 A
2.8 A/50 ms
Cable lengths
With RS 232
30 m (depending on baud rate)
Digital inputs/outputs None
Enclosure dimensions (L x W x H) in mm 320 x 145 x 100 (without connector)
Color Anthracite
Material Aluminum
Connector
Antenna
V24 interface
Power supply
TNC connector
9-pin Sub-D connector (male)
4-pin M12 connector (male)
Mounting 4 x M6 screws
Ambient temperature
Operation
Transport and storage
-20 °C to +55 °C
-25 °C to +70 °C
MTBF 7.5 x 10
4
hours
Degree of protection according to EN 60529 IP65 (UL: for indoor use only)
Shock resistant according to EN 60721-3-7 Class 7M2
Total shock response spectrum Type II
30 g