Alarm, error and system messages
11.1 Error messages and causes for MOBY D in combination with the MDWAPI library
MOBY D
System Manual, 01/2010, J31069-D0147-A6-7618
281
Table 11- 3 Parameter status
Error code
in HEX
Cause, remedy
0x10 EEPROM error:
EEPROM of the reader cannot be write-accessed
Before the write procedure in the EEPROM, a faulty parameter checksum occurred.
0x11 Parameter outside the valid range:
Valid parameter range exceeded.
Table 11- 4 Interface status
Error code
in HEX
Cause, remedy
0x80 Unknown command:
Selected function not supported by reader
0x81 Length error:
Protocol is too long or too short
0x82 Command is not possible:
0x83 HF communication error:
An error occurred in the communication between the transponder and reader.
Possible causes:
Algorithm for collision handling was not performed until no more collisions were
detected. Reason for interruption:
Timeout during communication with the host
0x94 Other data:
More transponder data records have been requested than the transponder protocol
is capable of transferring simultaneously.
0x95 ISO error:
Additional error code for ISO transponder was sent with the response data