Loading...
Mobile data storage units
5.4 MDS D124
MOBY D
System Manual, 01/2010, J31069-D0147-A6-7618
107
Flush-mounting
0HWDO
1RQPHWDO
'DWDPHPRU
\
K
D
h ≥ 25 mm
a ≥ 25 mm
Figure 5-8 Flush-mounting of MDS D124 in metal with spacer
Note
If the minimum guide values (h) are not observed, a reduction of the field data results. It is
possible to mount the MDS with metal screws (M3 countersunk head screws). This has no
tangible impact on the range.