System integration
MOBY D
230 System Manual, 01/2010, J31069-D0147-A6-7618
Overview
Table 9- 1 Overview of interface modules
ASM type Interfaces to
PC/computer
Interfaces to SLG Function
blocks
SLG
connections
Dimensions
(W x H x D
in mm)
Temperature
range
(during
operation)
Degree
of
protectio
n
ASM 452 PROFIBUS
DP-V1
2 x 5-pin BERO
connector
FC 45 1 134 x 110 x 55 0 to +55 °C IP67
ASM 456 PROFIBUS
DP-V1
2 x 8-pin
connection socket,
M12
FC 45
FB 45
FC 55
FB 55
2
(simultaneo
usly)
60 x 210 x 54 or
79
0 to +55 °C IP67
ASM 473 For inserting
in
ET 200X
2 x 5-pin
BERO connector
FC 45 1 87 x 110 x 55 0 to +55 °C IP67
ASM 475 For inserting
in
S7-300/
ET 200M
Through screw-
type terminals
FC 45 2
(simultaneo
usly)
40 x 125 x 120 0 to +60 °C IP20
RF170C Can be
plugged into
ET 200pro
8-pin M12
connector
FC 45
FB 45
FC 55
FC 56
2
(simultaneo
usly)
1)
90 x 130 x 60 -25 to +55 °C IP67
RF180C PROFINET 8-pin M12
connector
FB 45 2
(simultaneo
usly)
1)
60 x 210 x 30 0 to +60 °C IP67
RF182C TCP/IP 2 x 8-pin
connection socket,
M12
-- 2
(simultaneo
usly)
1)
60 x 210 x 30 0 to +60 °C IP67
1)
If 2 readers are used on one ASM, the following restrictions apply:
 The maximum operating temperature is 35 °C
 The input voltage is 24 V ±10%
Current consumption ≤ 425 mA per reader