Industrial cybersecurity
4.7 Secure operation of the system
S7-1500R/H redundant system
System Manual, 01/2024, A5E41814787-AF
45
List of all current vulnerabilities and detailed information such as:
Description
Classification according to Common Vulnerability Scoring System (CVSS)
Measures
Availability
Etc.
Report possible vulnerabilities yourself at
(https://new.siemens.com/global/en/products/services/cert.html#ContactInformation)
Set up an RSS feed to receive notifications about security-related topics.
4.7.7 Data backup
Secure your configuration and parameter settings so that you can quickly restore this data if
needed.
4.7.8 Security checks
Security checks for data, files, and archives serve to ensure data integrity at the storage
location and during file transmission, protecting against manipulation and transmission
errors. This is often achieved using digital checksums that are provided alongside the data.
Tools (such as SHA-256 or SHA-512) for calculating and verifying these checksums are
provided in many systems and named according to their respective calculation methods.
File Integrity Guidelines describe the prescribed procedure for integrity checks
Integrity protection is a protection function for engineering data and firmware files
Communication integrity means protecting communication against unauthorized
manipulations to ensure high system availability. A central element in this regard is, for
example, the use of digital checksums when accessing controllers. (Source: Industrial
Cybersecurity website (https://www.siemens.com/us/en/company/topic-
areas/cybersecurity/industrial-security.html))
4.7.9 Secure decommissioning
In the following section, you will find information on how to properly decommission
individual components of your SIMATIC S7-1500R/H redundant system. Decommissioning is
necessary when the component has reached the end of its service life.
Decommissioning includes environmentally sound disposal and secure removal of all digital
data of electronic components with storage medium.

Table of Contents

Other manuals for Siemens SIMATIC S7-1500T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC S7-1500T and is the answer not in the manual?

Siemens SIMATIC S7-1500T Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC S7-1500T
CategoryController
LanguageEnglish

Related product manuals