Descriptions (data position in Article No.)
1 2 3 4 5 6 7 - 8 9 10 11 12 - 13 14 15 16 - Z
Standard S/A R H
Advanced Life‐
time
6)
S/A R Q
Power connec‐
tion
Cable entry Signal connection (looking onto DE)
Terminal box
(top)
Right DE A
Terminal box
(top)
Left DE B
Terminal box
(top)
NDE Left C
Version
Version for potentially explosive atmospheres Zone 2 M03
Version for potentially explosive atmospheres Zone 22 M39
In the version for hazardous areas zone 2 and zone 22, the following options are not possible:
A12, A25, G14, K80, L74, Q12, U60, U61, U62, U63, U65, U66, U67, U68, Y64,
Z
1) Only possible if the 8th data position is "1" (induction version)
2) Limited to n
max
= 12,000r/min
3) Limited to n
max
= 9000 r/min
4) Limited to n
max
= 4600r/min
5) Only possible for shaft height 100, 132, and 160.
6) Limited to n
max
= 5000r/min, shaft height 132: n
max
= 4500r/min, shaft height 160: n
max
= 4000r/min
Motors for hazardous areas have been released for SINAMICS S120 or SINAMICS G120
converters (version with PM 240). Carefully comply with the following constraints when
operating the motors with third-party converters:
• Converters/inverters with pulse width modulation (PWM)
• The pulse clock frequency must be at least 4kHz
• Converter output voltage according to the following table
Line supply voltage Line Module (line-side converter/inverter infeed type) Converter output voltage
1
)
3 AC 400V Smart Line Module (SLM) unregulated 380V
Active Line Module (ALM) regulated 425V
3 AC 480V Smart Line Module (SLM) unregulated 460V
Active Line Module (ALM) regulated 500V
1)
Minimum output voltage required for motor operation in order to achieve data according to
the data sheet.
Motor components and options
5.2Options
1PH8 SIMOTICS M main motors
Conguration Manual, 12/2022, A5E51895839A 173