The rated powers for motors for use in hazardous zones are reduced both in S1 and S6 duty
in relation to the non-explosion protected version (standard version). The deratings are taken
into account in the rating plate data:
Article No. Version Derating
1PH8xxx-1xx1x-xxx1-Z, M03, or M39 Induction, forced ventilation 10%
1PH8xxx-1xx2x-xxx1-Z, M03, or M39 Induction, water cooling 20%
1PH8xxx-2xx1x-xxx1-Z, M03, or M39 Synchronous, forced ventilation 20%
1PH8xxx-2xx2x-xxx1-Z, M03, or M39 Synchronous, water cooling 20%
In hazardous areas of Zone 2 (option M03), for induction motor versions, reduce the
permissible maximum speeds (n
max
):
Article No. Version Maximum speed n
max
1PH810x-1xxxx-xxx1-Z, M03 Induction 4350r/min
1PH813x-1xxxx-xxx1-Z, M03 Induction 3000r/min
1PH816x-1xxxx-xxx1-Z, M03 Induction 2250r/min
The motors with forced ventilation have newly developed separately driven fans for use in
hazardous areas. These are in conformance with the applicable directives and standards. Take
the modied dimensions from dimension drawings (SIEMENS Product Congurator).
The supply values for the separately driven fans are specied in the following table:
Article No. Max. current consumption at
3 AC 400V / 50Hz
(±10%)
A
3 AC 400V / 60Hz
(±10%)
A
3 AC 480V / 60Hz
(±10%)
A
1PH810x-1xx1x-xxx1-Z, M03 or M39 0.16 0.13 0.16
1PH813x-1xx1x-xxx1-Z, M03 or M39
1PH813x-2xx1x-xxx1-Z, M03 or M39
0.26 0.24 0.28
1PH816x-1xx1x-xxx1-Z, M03 or M39
1PH816x-2xx1x-xxx1-Z, M03 or M39
0.25 0.22 0.27
Note
All of the separately driven fans are equipped with 3-phase motors.
Operating conditions for shaft heights 100 to 160
When operating SIMOTICS M-1PH8 motors in Zone 2 or Zone 22 hazardous areas, carefully take
into consideration the following application conditions:
• Provide specic operating instructions for the motors for when they are used in hazardous
areas (see link and documentation in the Intranet/Internet).
• Motor versions for use in hazardous areas are not UL-approved. As a consequence, these
motors do not bear the cUR marking.
Motor components and options
5.2Options
1PH8 SIMOTICS M main motors
174 Conguration Manual, 12/2022, A5E51895839A