Terminal
box type
Shaft
height
Cable entry
(power)
Cable entry
(external sig‐
nals)
Outer cable di‐
ameter, max.
mm
2)
Number of main ter‐
minals
Max. cross-
section
per
terminal
mm
2
Max.
current
per
terminal
A
3)
1XB7700-
P02
SH225
and
SH280
3 x M75 x 1.5 1 x M16 x 1.5
4)
68 Phases: 3 x 2 x M12
Grounding: 3 x
clamping plate
3 x 150 700
1XB7712-
P03
SH225
and
SH280
4 x M75 x 1.5 1 x M16 x 1.5
4)
68 Phases: 3 x 4 x M16
Grounding: 4 x M16
4 x 185 1150
1)
M16 x 1.5 thread arranged at 90° angle to signal connection; thread only with options A12, A25 and encoder version A
(without encoder)
2)
Depending on the version of metric cable gland (based on the MOTION-CONNECT cable type and cable glands from HUGRO
or from AGRO)
3)
Current-carrying capacity based on EN60204-1 and IEC60364-5-52, routing type E
4)
M16 x 1.5 thread arranged opposite to the signal connection (lateral to the cable entry plate); thread only for option A12 and
encoder version A (without encoder)
Note
Terminal box type 1XB7700-P02
For cable entry, 3 cable glands can only be t in if cable glands from AGRO or HUGRO are used.
Cable glands from Pitsch or Lapp, for example, are larger and it is not possible to t 3 of them
into the available space.
Terminal box design
① Terminal screw M5
② Grounding screw M5
③ Insulation strips
Figure9-7 Terminal box gk803, 3-pole (SH 80)
Electrical connection
9.3System integration
1PH8 SIMOTICS M main motors
232 Conguration Manual, 12/2022, A5E51895839A