Table 6-5 Select connection macro C05 with the operator panel after the wiring (please refer to 
"Operation mode ② - Connection macro selection", and then below parameter settings 
will be automatically finished.)
Par. No. Parameter name Range Unit Default
r0007 Selected connection macro and application macro C0100 - C1105 - - C05xx*
P0610 Motor I
2
t reaction 0 - 2 - -  1
P0701 Function of digital input 1 0 - 99 - -  99
P0702 Function of digital input 2 0 - 99 - - 1
P0703 Function of digital input 3 0 - 99 - - 0
P1000 Selection of frequency setpoint 0 - 53 - - 2
P0725 PNP/NPN digital inputs 0 - 1 - - 1
* "xx" means current application macro.
Commissioning 
6.1 Typical connection modes
SINAMICS V10
Operating Instructions, 08/2011, A5E03453178 (this is not an order number) 47