Excessively high speed during incorrect control of the Safely-Limited Speed limits via F-DI
For all control options except PROFIsafe, limit SLS1 is activated after 2 discrepancy errors that
have not been acknowledged. This means that for the 2 F-DIs for selecting the velocity levels,
the value 0 is the "safe state" (failsafe value).
Therefore parametrize the SLS limits in ascending order, i.e. with limit SLS1 as the lowest
speed and limit SLS4 as the highest speed.
Responses
Speed limit value exceeded:
Configured subsequent stop STOP A/B/C/D/E via p9563
Safety message C01714
System fault:
STOP F
Safety messages C01711
Transferring the first limit value via SIEMENS telegram 901, 902 or 903
You have the option of influencing the first SLS limit value via PROFIsafe:
The transfer of the first SLS limit value via PROFIsafe is active if the speed level 1 in the
PROFIsafe telegram is selected and the bit "Enable transfer SLS (SG) limit via PROFIsafe"
(p9501.24) is set.
S_SLS_LIMIT_A has the value range 1 ... 32767; the following applies:
32767 ≙ 100 % of the 1st SLS level
The actually monitored limit value is calculated as follows:
SLS limit value = (S_SLS_LIMIT_A/32767) × p9531[0]
Also in this case, speed levels 2, 3 and 4 can be parameterized and selected.
In operation, the selected delay time cannot be changed. If you require various delay times
in your application, then you must realize this using a time-delayed transfer of the SLS limit
value using the F-PLC.
If an incorrect SLS limit value is transferred, then the converter responds with the stop
response of speed level 1 parameterized in p9563.
Safety functions integrated in the drive
4.10 SLS
Safety Integrated (with SINAMICS S120)
Commissioning Manual, 02/2020, A5E46305916B AB 141

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK MC and is the answer not in the manual?

Siemens SINUMERIK MC Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK MC
CategoryControl Systems
LanguageEnglish

Related product manuals