Page #29 background imageLoading...
Page #29 background image
Details for internally processing the safety-related communication
6DIHW\
SURJUDP
7UDQVIHU
$;$;
6,&6&&
,IUHTXLUHG
DGGLWLRQDO
GULYHV
0RQLWRULQJ
$;$;
6,1$0,&6
'ULYH
66
00
$;
)3/&
'%'%
6,&6&&
352),VDIH
$;$;
3$(
3$$
)',
)'2
1&
PROFINET/
PROFIsafe
6,180(5,.0&
0&8
PROFINET/
PROFIsafe
Figure 2-2 Component diagram for processing safety-relevant information and data
Table 2-4 Subcomponents of SINUMERIK MC
F-PLC
PROFIsafe host
Processing safety-relevant internal and external signals in the safety-relevant
user program (safety program).
See: Safety program of the F-PLC (Page 53)
Processing status and control signals (SIC/SCC) via the corresponding axis
DB (LBP_Axis1 [DB31] ... LBP_Axis8 [DB38]).
See: PLC user interface (DB3x) (Page 213), SIC/SCC (Page 212)
NC
Transfers status and control information (SIC/SCC, axis DB) between the F-
PLC and SINAMICS S drive.
Reads-in safety-relevant messages/signals from the message buffers of the
SINAMICS drive into the NC alarm buffer.
Fundamentals
2.6 Safety-relevant processing using MC components
Safety Integrated (with SINAMICS S120)
Commissioning Manual, 02/2020, A5E46305916B AB 29

Table of Contents