Appendix
A.9 Information List
SIPROTEC, 7SD80, Manual
E50417-G1140-C474-A1, Release date 09.2011
390
10329 27-Vphph Pickup C-A (27-Vpp
PU CA)
27/59 O/U Volt. OUT * On
Off
* LED BO 73 129 2 Yes
10330 27-1-Vphph TimeOut (27-1-Vpp-
TimeOut)
27/59 O/U Volt. OUT * * * LED BO
10331 27-2-Vphph TimeOut (27-2-Vpp-
TimeOut)
27/59 O/U Volt. OUT * * * LED BO
10332 27-Vphph TRIP command (27-
Vpp TRIP)
27/59 O/U Volt. OUT * ON * LED BO 73 132 2 Yes
10333 27-1-Vphph Pickup A-B (27-1-
Vpp PU AB)
27/59 O/U Volt. OUT * * * LED BO 73 151 2 Yes
10334 27-1-Vphph Pickup B-C (27-1-
Vpp PU BC)
27/59 O/U Volt. OUT * * * LED BO 73 152 2 Yes
10335 27-1-Vphph Pickup C-A (27-1-
Vpp PU CA)
27/59 O/U Volt. OUT * * * LED BO 73 153 2 Yes
10336 27-2-Vphph Pickup A-B (27-2-
Vpp PU AB)
27/59 O/U Volt. OUT * * * LED BO 73 154 2 Yes
10337 27-2-Vphph Pickup B-C (27-2-
Vpp PU BC)
27/59 O/U Volt. OUT * * * LED BO 73 155 2 Yes
10338 27-2-Vphph Pickup C-A (27-2-
Vpp PU CA)
27/59 O/U Volt. OUT * * * LED BO 73 156 2 Yes
17525 85 DT: Received 3pole (85 DT
rec.3pole)
85 DT Intertrip OUT On
Off
**LEDBO
17526 85 DT: Sending 3pole (85 DT
sen.3pole)
85 DT Intertrip OUT On
Off
**LEDBO
17530 67(N) Backup O/C is BLOCKED
(67(N) BLOCK)
Back-Up O/C OUT * ON * LED BO 64 148 2 No
17531 67(N) Backup O/C is ACTIVE
(67(N) ACTIVE)
Back-Up O/C OUT * ON * LED BO 64 149 2 No
17532 Backup O/C stage 67(N)-B2 is
sw. OFF (67(N)-B2 OFF)
Back-Up O/C OUT * ON * LED BO
17533 Backup O/C stage 67(N)-B1 is
sw. OFF (67(N)-B1 OFF)
Back-Up O/C OUT * ON * LED BO
17534 Backup O/C stage 67(N)-TOC is
sw. OFF (67(N)-TOC OFF)
Back-Up O/C OUT * ON * LED BO
17535 67(N) Backup O/C PICKED UP
(67(N) PICKUP)
Back-Up O/C OUT * on * LED BO
17536 67 Backup O/C PICKUP Phase A
(67 Pickup ØA)
Back-Up O/C OUT * on * LED BO
17537 67 Backup O/C PICKUP Phase B
(67 Pickup ØB)
Back-Up O/C OUT * on * LED BO
17538 67 Backup O/C PICKUP Phase C
(67 Pickup ØC)
Back-Up O/C OUT * on * LED BO
17539 67N Backup O/C PICKUP
GROUND (67N Pickup Gnd)
Back-Up O/C OUT * on * LED BO
30053 Fault recording is running (Fault
rec. run.)
Osc. Fault Rec. OUT * * * LED BO
31000 Q0 operationcounter= (Q0
OpCnt=)
Control Device VI
31001 Q1 operationcounter= (Q1
OpCnt=)
Control Device VI
31002 Q2 operationcounter= (Q2
OpCnt=)
Control Device VI
31008 Q8 operationcounter= (Q8
OpCnt=)
Control Device VI
31009 Q9 operationcounter= (Q9
OpCnt=)
Control Device VI
No. Description Function Type
of In-
for-
matio
n
Log Buffers Configurable in Matrix IEC 60870-5-103
Event Log ON/OFF
Trip (Fault) Log ON/OFF
Ground Fault Log ON/OFF
Marked in Oscill. Record
LED
Binary Input
Function Key
Relay
Chatter Suppression
Type
Information Number
Data Unit
General Interrogation