Commissioning
4.7 Basic parameterization of the drive objects
Commissioning with Startdrive
Commissioning Manual, 11/2017, 6SL3097-4AA10-0BP1
169
Changing the view of the screen form
The view of this screen form can be reduced to the essentials via a checkbox. Changing the
function of one of the bidirectional digital inputs/outputs is not possible in the optimized view.
The view of the screen form can also be switched to a simulation mode. This switchover only
functions in online mode.
1. If you want to optimize the view, activate the "Optimize view" option.
2. If you want to switch to a simulation from the terminal evaluation, select "Simulation" in
the drop-down list of a digital input.
Parameterizing digital inputs 8 … 15 or digital outputs 8 … 15
Each of the bidirectional digital inputs/outputs can be parameterized as an input or output
using the selector.
Digital input
Default setting when calling the screen form the first time.
Digital inputs 8 ... 15 can be interconnected with this switch position. Several
interconnections are possible.
The selector can be switched by clicking from digital input to digital output.
Digital output
Digital outputs 8 ... 15 can be interconnected with this switch position. Several
interconnections are possible.
The selector can be switched by clicking from digital output to digital input.
1. Select the digital input/output on the required terminal.
2. Connect the signal source of the digital input (8 ... 15).
- Or -
3. To change the digital input to a digital output, proceed as follows:
– Click the selector.
– Then connect the signal sink of the digital output (8 ... 15).
– Invert the digital output when required.
4. Repeat steps 2 or 3 for all digital inputs/outputs of the required terminal.