Commissioning
4.11 Configuring brake control
Commissioning with Startdrive
290 Commissioning Manual, 11/2017, 6SL3097-4AA10-0BP1
Commissioning
Simple brake control is activated automatically (p1215 = 1) when the Motor Module has an
internal brake control and a connected brake has been found.
If no internal brake control is available, the control can be activated via parameter (p1215 =
3).
WARNING
Danger as a result of a damaged holding brake caused by incorrect parameter assignment
If the drive moves against the closed holding brake, this can destroy the holding brake and
as a consequence result in death or severe injury.
• If a holding brake is being used, do
not
set the parameter assignment p1215 = 0.
• Correctly set all of the parameters involved.
Note
It is only permissible to activate br
ake control monitoring for booksize power units and
blocksize power units with Safe Brake Relay (p1278 = 0).
4.11.2.2
Parameterizing the brake control
Selecting the type of brake control
WARNING
Danger as a result of a damaged holding brake caused by incorrect parameter assignment
If the drive moves against the closed holding brake, this can destroy the holding brake and
cause death or serious injury.
• Do
not
set the parameter assignment p1215 = 0 when there is a holding brake.
• Set all the relevant parameters correctly.

Table of Contents

Other manuals for Siemens SIROTEC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIROTEC and is the answer not in the manual?

Siemens SIROTEC Specifications

General IconGeneral
BrandSiemens
ModelSIROTEC
CategoryDC Drives
LanguageEnglish

Related product manuals