Commissioning
4.11 Configuring brake control
Commissioning with Startdrive
Commissioning Manual, 11/2017, 6SL3097-4AA10-0BP1
305
Function diagrams and parameters
Function diagrams (see SINAMICS S120/S150 List Manual)
2701
- Simple brake control (r0108.14 = 0)
2704
- Extended brake control,
stationary state detection (r0108.14 = 1)
2707
- Extended brake control, open/close brake
2711
- Extended brake control,
signal outputs (r0108.14 = 1)
Overview of important parameters (see SINAMICS S120/S150 List Manual)
r0108.14
Drive objects, function module;
r0899.0...15
CO/BO: Status word, sequence control
r0060
CO: Speed setpoint before the setpoint filter
r0063
CO: Actual speed value smoothed
r0063[0...2]
p1224[0...3]
BI: Close motor holding brake at standstill
p1225
CI: Standstill detection th
reshold value
p1226[0...n]
Standstill monitoring speed threshold
p1227
Standstill detection monitoring time
p1228
Pulse suppression delay time
p1276
Motor holding brake standstill detection bypass
p0855[0...n]
ally open holding brake
p0856[0...n]
BI: Speed controller enabled
p0858[0...n]
BI: Unconditionally close holding brake
p1216
Motor holding brake opening time
p1217
Motor holding brake closing time
p1218[0...1]
BI: Open motor holding brake
p1219[0...3 ]
BI: Immediately close motor holding brake
p1220
CI: Open motor holding brake, signal source, threshold