Appendix
A.5 System rules, sampling times and DRIVE-CLiQ wiring
Commissioning with Startdrive
Commissioning Manual, 11/2017, 6SL3097-4AA10-0BP1
401
A.5.4.2
Recommended interconnection rules
The following recommended rules should be observed for the DRIVE-CLiQ wiring:
General
The following applies to all DRIVE-CLiQ components with the exception of the Control
Unit: The DRIVE-CLiQ sockets Xx00 are DRIVE-CLiQ inputs (Uplink), the other DRIVE-
CLiQ sockets are outputs (Downlink).
The DRIVE-CLiQ cable from the Control Unit should be connected to DRIVE-CLiQ
socket X200 on the first booksize power unit.
The DRIVE-CLiQ connections between the power units should each be connected
from the DRIVE-CLiQ sockets X201 to X200 and/or X401 to X400 on the follow-on
component.
Line Modules
An individual Line Module should be connected directly to the Control Unit (recommended
DRIVE-CLiQ socket: X100).
Several Line Modules should be connected in series.
Motor Modules
No more than 6 Motor Modules should be connected to a DRIVE-CLiQ line on the Control
Unit (including with vector, V/f control).
Motor Modules should be connected directly to the Control Unit in vector control.
If DRIVE-CLiQ socket X100 is already assigned to a Line Module, DRIVE-CLiQ socket
X101 should be used.
Several Motor Modules should be connected in a line.
In servo control Motor Modules should be connected to a DRIVE-CLiQ line together with
the Line Module.
Several Motor Modules should be connected in a line.
If there is already a Line Module present, the first Motor Module should be connected
in line to socket X201 of the Line Module.
If there is no Line Module present, the first Motor Module should be connected directly
to the Control Unit (recommended DRIVE-CLiQ socket: X100).
If the Motor Modules need to be distributed across two DRIVE-CLiQ lines (e.g. on
account of the specified current controller sampling times), the next higher DRIVE-CLiQ
socket on the Control Unit should be used.
Only one end node should be connected to free DRIVE-CLiQ sockets within a DRIVE-
CLiQ line (e.g. Motor Modules wired in a line), for example, one Sensor Module, without
routing to additional components.
For mixed operation of the servo control and vector V/f control, separate DRIVE-CLiQ
lines should be used for the Motor Modules.

Table of Contents

Other manuals for Siemens SIROTEC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIROTEC and is the answer not in the manual?

Siemens SIROTEC Specifications

General IconGeneral
BrandSiemens
ModelSIROTEC
CategoryDC Drives
LanguageEnglish

Related product manuals