Commissioning
4.10 Safety Integrated commissioning
Commissioning with Startdrive
250 Commissioning Manual, 11/2017, 6SL3097-4AA10-0BP1
Configuring the brake test via test stop selection
1. Select the "Test stop selection" setting in the "Select SBT" drop-down list.
2. Select the direction of the test torque for SBT in the "Test direction" drop-down list.
3. Select the "Test motor holding brake" setting in the "Brake 1" drop-down list.
4. Select the "Disable" setting in the "Brake 2" drop-down list.
5. Set the following information in the input fields for Brake 1:
– Test duration (p10211[0])
– Holding torque (p10209[0])
– Position tolerance (p10212[0])
– Ramp time (p10209[0])
– Factor (p10210[0])
6. Click "Save project" in the toolbar to save the changes in the project.