3
Siemens Site [1] SITE1
Kinematic Viscosity of liquid
Liquid Data
Viscosity <cS> 1.00
Density S.G. 1.000
Selecting Pipe Data
z Press the <Down> arrow to select Pipe Data, then press the <Right> arrow.
Siemens Site [1] SITE1
Enter Pipe Outer Diameter manually
Pipe Data
Pipe OD (in) 1.000
Pipe Material Steel
Wall Thickness 0.035
Liner Material None
Liner Thickness 0.000
z Press the <Right> arrow and use numeric keys to change Viscosity <cS>. Press <ENT>
to register data.
z Press the <Right> arrow and use numeric keys to change Density SG. Press <ENT> to
register data.
z To select Pipe OD (in), press the <Right> arrow. Use numeric keys to change pipe size.
Press the <ENT> key to register data.
z Press the <Down> arrow to select Pipe Material if it is not displayed, then press the
<Right> arrow to select option list.
z Use the <Up> and <Down> keys to scroll the option list for the desired pipe material.
Press the <ENT> key to register data.
z Press <Down> arrow to select Liner Material if it is not displayed, then press the <Right>
arrow to select option list.
z Use the <Up> and <Down> keys to scroll the option list for the desired liner material.
Press the <ENT> key to register data.
z Press the <Down> arrow to select Liner Thickness, then press <Right> arrow. Use nu-
meric keys to change pipe size. Press the <ENT> key to register data.
Liquid Data
z Press the <Down> arrow to select Liquid Data if it is not displayed, then press the <Right>
arrow.